![]() You may need to reset the sensors for it to show up and sometimes it takes 15 to 20 minutes the first time after the VIB install and reboot of the ESXi Host. When you add the Dell OMSA VIB to the ESXi Host you will see a Storage sensor added to the Health Status page which shows the RAID volumes, drives, controller and battery health for your storage controller. You do see some minor additional hardware health details when you connect to a vCenter server versus the ESXi Host directly but generally if you do not see the hardware health you are looking for in the Configuration/ Health Status panel then you are missing a CIM provider and you need to locate and install the VIB on the ESXi Host. Show the currently installed VIBs on the ESXi Host from the Host's CLI, Show the current CIM providers on an ESXi Host You will not see the RAID Health information in the DRAC or iDRAC though - only when connecting the OMSA Server to an ESXi Host - I repeat the Server keyword so there is no confusion between the Server which is acting as a client to the OMSA VIB that is installed on the ESXi Host. You can use the OMSA server to connect to DRAC and iDRAC Out of Band (OOB/ IPMI/ iLo) management cards or to the ESXi Host after you install the OMSA VIB on the ESXi Host. If you wish to use the Dell OMSA Server you can install it remotely on bare bones server, remotely in a VM or locally as a VM. You only need to follow the instructions for installing the OMSA ESXi VIB if you are going to use a third party monitoring tool that gives historical information and does alerting. Brian Atkinson's post is still the best I have found that describes the process, You will need to add the Dell OMSA VIB that adds the additional CIM agents including the one for the RAID array. There are 5 or 6 CIM modules built into ESXi 5.5 that give you hardware health but RAID card health is not one of them. ![]() Yes, you can monitor the standalone ESXi Host using any SNMP monitoring software but some items may only be visible using a monitoring tool that supports the CIM protocol.Īll of my ESXi Hosts are part of vCenter but we monitor them directly (using the vmkernal Host IP address) with SolarWinds NPM. Is what I am trying to do possible (without a complete vSphere environment) even possible? I imagine this being a fairly common requirement, yet the docs available pull one in all different directions. Then there is the OMSA VIBs one can install, etc. I have conflicting information whether this is even possible at all, some documents say that you cannot query a DELL VMWare ESXi server via SNMP and you need to use a CIM client. ![]() I was under the impression that installing the VMWare version from DELL would automagically enable the necessary modules (OpenManage most importantly), but it seems like that is not the case. I'd like to see information from temperature sensors, installed disks and their status, fan speed, PSU status etc. What I would like to accomplish seems simple: Configure the system so that it can be queried via SNMP from a remote host, whether it's snmpwalk, Nagios, PRTG etc. We have a bunch of VMWare ESXi 5.5 servers, some of which are integrated into vSphere, some of which are not (for cost reasons).Īll of them run the standard ESXi image, with the exception of one machine which is actually running the DELL VMWare ESXi image. Despite researching this topic quite a bit online (to be fair I'm not a full time sysadmin) I'm unable to figure this out. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |